Verified 5V0-21.21 dumps Q&As - 100% Pass from Prep4King [Q19-Q36]

Share

Verified 5V0-21.21 dumps Q&As - 100% Pass from Prep4King

Pass 5V0-21.21 Exam in First Attempt Guaranteed 2021 Dumps!

NEW QUESTION 19
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?

  • A. There will be no impact on performance.
  • B. The performance will be degraded.
  • C. The VMs will no longer be accessible.
  • D. The VMs will be in a suspended state.

Answer: A

 

NEW QUESTION 20
An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.
Which additional step should the administrator take to ensure no data is lost during the encryption process?

  • A. Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.
  • B. Select 'Erase disks before use' check box when enabling encryption on a vSAN cluster.
  • C. Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.
  • D. Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.

Answer: B

 

NEW QUESTION 21
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • B. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
  • C. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • D. Change the FTT setting in Policy 3 to be "Erasure Coding".
  • E. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".

Answer: A,E

 

NEW QUESTION 22
An architect is tasked to design a VMware Horizon Solution with vSAN. The architect needs to use a solution to host the user's profile shares in a highly available manner, and it must be guest OS independent.
Which solution will match these requirements?

  • A. Cluster in a box
  • B. NFS on vSAN
  • C. iSCSI on vSAN
  • D. Cluster out of the box

Answer: C

 

NEW QUESTION 23
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)

  • A. There is a vSAN node failure.
  • B. The object repair timer value has been increased.
  • C. The vSAN Resync throttling is enabled.
  • D. The vSAN policy protection level has changed from FTT=0 to FTT=1.
  • E. The cluster DRS threshold has been set to Aggressive.

Answer: C,D

 

NEW QUESTION 24
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?

  • A. The cluster will be partitioned and the vSAN host will need to be rejoined.
  • B. All objects will remain accessible.
  • C. A rebuild of the affected objects will occur.
  • D. All objects on the affected host will be lost.

Answer: C

 

NEW QUESTION 25
An 8-Node vSAN Stretched Cluster (4+4+1) with a single disk group has a policy with PFTT=1 (mirrored across sites) and SFTT=1/FTM Mirroring (Local Protection) configured.
The administrator has been alerted that there is a problem with the cluster. The following has been observed:
* The vSAN Witness Host is offline.
* Two disk failures on two hosts have occurred in the preferred site.
This has resulted in a critical production virtual machine's vmdk becoming inaccessible.
Which step needs to be performed by the administrator to resolve the issue?

  • A. Replace only one failed disk on the preferred site.
  • B. Replace access to the existing vSAN Witness Host
  • C. Replace all failed disks on the preferred site.
  • D. Replace the vSAN Witness Host

Answer: B

 

NEW QUESTION 26
An architect is working with vSAN and setting the fault domains to support FTT=1.
How many fault domains will be needed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 27
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?

  • A. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
  • B. Replace the caching device in each affected disk group.
  • C. Restore the communication with the KMS server, and re-establish the trust relationship.
  • D. Manually replace the Host Encryption Key (HEK) of each affected host.

Answer: C

 

NEW QUESTION 28
During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.)

  • A. /etc/init.d/vsanobserver restart
  • B. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
  • C. /etc/init.d/vsanmgmtd restart
  • D. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
  • E. /etc/init.d/clomd restart

Answer: D,E

 

NEW QUESTION 29
A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.
The following requirements must be met:
* Each MSSQL cluster is made up of 3 nodes
* Highest possible availability against node failures
* Some of the vSAN clusters will only consume storage
What should the architect recommend?

  • A. vSAN Direct
  • B. vSAN iSCSI Target Service
  • C. Stretched vSAN Cluster
  • D. vSAN File Services

Answer: B

 

NEW QUESTION 30
An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.
Which version of Kerberos must be selected if the NFS version is v4.1?

  • A. krb5
  • B. krb5i
  • C. krb5p
  • D. krb4

Answer: B

 

NEW QUESTION 31
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?

  • A. vSAN network diagnostic mode is not enabled.
  • B. vSAN proactive tests haven't been run yet.
  • C. vSAN performance service is turned off.
  • D. vSAN performance verbose mode is not enabled.

Answer: C

Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.

 

NEW QUESTION 32
During a design workshop for a stretched vSAN cluster, the requirement that some of the VMs be configured with no-mirror between sites was discussed.
Which three recommendations should the architect provide to address an event of a network partition between two sites? (Choose three.)

  • A. VMware vSphere DRS rules to force the VMs to run where the data resides
  • B. One of isolation addresses should reside in the site 1 data center
  • C. The default gateway must be used as the only isolation address
  • D. Host isolation response must exclude the VMs required
  • E. One isolation address reachable only from the witness appliance in both sites
  • F. One of isolation addresses should reside in the site 2 data center

Answer: A,D,F

 

NEW QUESTION 33
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?

  • A. A 16GB single-level cell (SLC) SATADOM device must be used.
  • B. ESXi Hosts must boot from a PMEM device.
  • C. A 4GB USB or SD device must be used.
  • D. A 16GB multiple-level cell (MLC) SATADOM device must be used.

Answer: D

 

NEW QUESTION 34
An architect is designing a vSAN cluster.
Which storage controller option will yield optimal performance?

  • A. Hugh queue depth
  • B. Set caching to 50% read on the controller
  • C. RAID 0
  • D. Enable battery write-back caching

Answer: C

 

NEW QUESTION 35
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

  • A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
  • B. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
  • C. Install an additional 3 x 1.8 TB SSDs per vSAN node.
  • D. Update the existing Disk Group, and claim the newly installed drives for each node.
  • E. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.

Answer: B,C

 

NEW QUESTION 36
......


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution
Topic 2
  • Performance-tuning, Optimization, Upgrades
  • Given a scenario, identify the appropriate vSAN upgrade methodology
Topic 3
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 4
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Installing, Configuring, ana Setup
Topic 5
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 6
  • identify the tasks to manape a stretches vSAN cluster
  • Identify the operational tasks required to manape an encrypted vSAN
Topic 7
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure

 

5V0-21.21 Dumps Full Questions - Exam Study Guide: https://www.prep4king.com/5V0-21.21-exam-prep-material.html

Use Real 5V0-21.21 - 100% Cover Real Exam Questions: https://drive.google.com/open?id=19ZJ2_pAT7uExuzh-pT_Bvj1_KvVmNl1W