
[2024] Use Valid New E-S4HCON2023 Test Notes & E-S4HCON2023 Valid Exam Guide
E-S4HCON2023 Actual Questions Answers PDF 100% Cover Real Exam Questions
NEW QUESTION # 24
You are performing an upgrade of an SAP ECC development system with SUM. What is the earliest point when the upgrade is considered complete and you can allow all dialog users to log on to the system?
Please choose the correct answer.
Response:
- A. After the SUM roadmap step "Execution" is finished and before "Postprocessing"
- B. During the SUM roadmap step "Postprocessing", in parallel with post procedure steps
- C. After the SUM roadmap step "Postprocessing" and post procedure steps are finished
- D. During the SUM roadmap step "Postprocessing", after the post procedure steps are complete
Answer: D
NEW QUESTION # 25
You are performing an SAP S/4HANA conversion with DMO. You are using the downtime-optimized data conversion (DoC). Which steps can partially be moved to uptime processing? Note: There are 2 correct answers to this question.
- A. Software update
- B. Main import
- C. Conversion
- D. Migration
Answer: C,D
NEW QUESTION # 26
What can you achieve by setting the SUM parameter "migration_only" to 1 in parameter file SAPup_add.par?
Please choose the correct answer.
Response:
- A. A migration of the SAP system to a new hardware is performed, without performing an SAP S/4HANA conversion.
- B. An upgrade of the software components is performed, without changing the database type.
- C. A change of the database type is performed, without changing the software components.
- D. An SAP S/4HANA conversion is performed, without adapting the customer data.
Answer: C
NEW QUESTION # 27
You are starting an SAP S/4HANA Conversion. The scenario strategy Downtime Optimized Conversion (DoC) is NOT selectable.What could be the reason?
- A. The start release is too old for DOC.
- B. The SAP S/4HANA Conversion is without DMO.
- C. The source database is not supported
- D. The SAP S/4HANA Conversion includes a DMO.
Answer: C
NEW QUESTION # 28
During the configuration of the DMO for SUM, how does the tool behave if option "Do not compare table contents" is selected regarding table comparison?
Please choose the correct answer.
Response:
- A. It performs a comparison on selected tables using check sum.
- B. It does NOT perform any table comparison.
- C. It performs a comparison on all tables using row counts.
- D. It performs a comparison of all tables using check sum.
Answer: C
NEW QUESTION # 29
You are planning an SAP S/4HANA conversion. Which conversion-specific tasks need to be performed during the preparation phase?
There are 2 correct answers to this question.
Response:
- A. Perform the migration of data into the new data structure
- B. Run the database migration to the SAP HANA database
- C. Check the compatibility of custom code with SAP S/4HANA
- D. Apply the recommendations of the simplification list
Answer: C,D
NEW QUESTION # 30
The SUM procedure stops with an error during uptime. How can you identify the current phase, the one in which SUM encountered an error?
There are 2 correct answers to this question.
Response:
- A. Check the most recent entries shown in file sapevt.trc
- B. Check the system log (transaction SM21) of the SAP system
- C. Check the most recent entries in SAPup.log
- D. Check the messages shown by the SUM UI
Answer: C,D
NEW QUESTION # 31
Which of the following SUM activities require a stack XML file calculated by the maintenance planner?
Note: There are 3 correct answers to this question.
- A. SAP S/4HANA conversion without DMO
- B. Prerequisite check
- C. Benchmark tool
- D. SAP S/4HANA conversion including DMO
- E. DMO without system update
Answer: A,B,D
NEW QUESTION # 32
ICNV initialization does 3
- A. Build index on flag column
- B. AA
- C. Creation of flag
- D. Creation of views
Answer: A,C,D
NEW QUESTION # 33
You are executing a standard SUM procedure to update an SAP system using main configuration mode "Standard". When will the shadow system be stopped for the last time?
Please choose the correct answer.
Response:
- A. As part of the cleanup process
- B. Before the downtime starts
- C. At the end of the downtime
- D. Early in the downtime
Answer: B
NEW QUESTION # 34
You are running an SAP ECC system.
For which of the following activities does SUM allow you to use the near-Zero Downtime Maintenance (nZDM) capabilities?
Note There are 3 correct answers to this question
- A. Use DMO for SUM
- B. Upgrade the SAP system
- C. Apply SAP support packages
- D. Perform an SAP S/4 HANA conversion without DMO
- E. Perform an SAP S/4 HANA conversion including DMO
Answer: A,B,C
NEW QUESTION # 35
What do you need to know about the SAP ERP Upgrade and Update Guide?
There are 2 correct answers to this question.
Response:
- A. It is target release specific
- B. It is a database-specific document
- C. It contains a section "free space requirements"
- D. It contains a troubleshooting section
Answer: A,C
NEW QUESTION # 36
What do you need to consider when performing the SI checks for an SAP S'4I 1ANA conversion? Note There are 2 correct answers to this question.
- A. You need an SAP system based on AS ABAP 7.50 or above for the SI check framework
- B. The SI checks are executed in the development system and the results are transported into the subsequent systems
- C. The errors from the SI checks must be solved, otherwise. SUM will report an error
- D. You need to build up an SI check framework by applying SAP Notes
Answer: A,D
NEW QUESTION # 37
You are planning to upgrade your SAP ECC 6.07 system running on a single codepage (SCP) to SAP ECC 6.08. What is the recommended option to perform this upgrade?
Please choose the correct answer.
Response:
- A. Perform the Unicode conversion before the upgrade to SAP ECC 6.08.
- B. Combine the upgrade and the Unicode conversion using the Twin Upgrade &Unicode Conversion (TU &UC) procedure.
- C. Combine the upgrade and the Unicode conversion using the Combined Upgrade &Unicode Conversion (CU &UC) procedure.
- D. Perform the upgrade to SAP ECC 6.08 before the Unicode conversion.
Answer: A
NEW QUESTION # 38
You are performing an S/4HANA conversion of the development system. Which credentials do you use in which system to perform the adjustment of dictionary objects (SPDD)?
Please choose the correct answer.
Response:
- A. Credentials of a named user in the development client of the development system
- B. Credentials of a named user in client 000 of the shadow system
- C. Credentials of user DDIC in the development client of the development system
- D. Credentials of user DDIC in client 000 of the shadow system
Answer: B
NEW QUESTION # 39
What are the benefits of using the benchmarking option of the DMO for SUM? Note There are 2 correct answers to this question
- A. You can record the modification adjustment during migration and use the transports in the next runs.
- B. You can verify that the content of the download directory matches the stack XML file.
- C. You can find the optimal number of parallel H3load processes by monitoring host performance
- D. You can obtain migration duration tiles from a previous benchmark run that can be used to optimize the next runs
Answer: C,D
NEW QUESTION # 40
You want to perform custom code check via ABAP test cockpit in preparation of your SAP S/4HANA conversion? What kind of SAP System can you use to generate the custom code migration worklist?
- A. AA
- B. A Standalone SAP system with ABAP 7.51 or above
- C. An SAP S4HANA 1709 sandbox system
Answer: B,C
NEW QUESTION # 41
What SAP systems can you use for the ABAP Test Cockpit (ATC) to perform the custom code analysis for an SAP S/4HANA conversion? Note: There are 2 correct answers to this question.
- A. SAP Solution Manager 7.2
- B. Standalone AS ABAP with SAP_BASIS 752 and above
- C. SAP ECC system from SAP ERP 6.0 EHP 8
- D. SAP S/4HANA Server 1809 and above
Answer: B,D
NEW QUESTION # 42
You performed a custom code check for an SAP S/4HANA conversion. In which transactions can you review the results?
There are 2 correct answers to this question.
Response:
- A. ATC (ABAP Test Cockpit)
- B. SE80 (Object Navigator)
- C. SAT (Runtime Analysis)
- D. SYCM (Simplification Database Content)
Answer: A,B
NEW QUESTION # 43
SUM was registered at the SAP Host Agent. Based on which information does the SAP Host Agent determine the path to the SUM directory.
- A. The path is taken from the URL entered in the browser to start SUM
- B. The path was stored to the environment of user <sid>adm during registration
- C. The path was stored in file sumabap conf during registration
- D. The path was stored in file host_profile during registration
Answer: C
NEW QUESTION # 44
You are upgrading a three-system landscape DEV - QAS - PRD. The upgrade project contains a Unicode conversion. You have already upgraded the DEV and the QAS system but not yet the PRD system. What do you need to consider? Please choose the correct answer.
- A. The transport between Unicode and non-Unicode systems is forbidden.
- B. The upgrade of the PRD must be finished before you start new development in the DEV.
- C. The upgrade of the PRD must be finished before you import any transports from the upgraded DEV system into the PRD.
- D. The transport domain of systems DEV and QAS must differ from the transport domain of system PRD.
Answer: C
NEW QUESTION # 45
You are planning an SAP S/4HANA conversion.
Which conversion-specific tasks must be performed during the preparation phase?
- A. Solve problems from the simplification item (SI) checks.
- B. Perform the migration of data to the new data structure.
- C. Run the database migration to the SAP HANA database.
- D. Check the compatibility of custom code with SAP S/4HANA.
Answer: D
NEW QUESTION # 46
You are performing an SAP S/4HANA conversion. Which phases are executed during SUM technical downtime? Note: There are 2 correct answers to this question
- A. PARMVNT_UPG
- B. PARDIST_SHD
- C. TABIMJJPG
- D. TABIM_SHADOW_*
Answer: C
NEW QUESTION # 47
......
E-S4HCON2023 Exam questions and answers: https://www.prep4king.com/E-S4HCON2023-exam-prep-material.html
Pass E-S4HCON2023 Exam Info and Free Practice Test: https://drive.google.com/open?id=1O0bf9G0JRPZRCG5IJZ2L6iYDLigD6-Nb

